Injection molding / RPM mode
Production Settings
Set speed: Set motor speed (RPM)
Dos.time : Actual feeding time (sec), measured from relay
Test : Initial production test with set speed and time
Actual production data
Speed : Actual motor speed (RPM)
Time : Count down of the actual feeding time (sec)
Status : Status of the feeding, standby/feeding/filling
How can I select a calibrated material?
When one or more material calibrations are made, one of these can be selected as follows:
Go to MATERIAL menu
Press and hold the “ENTER” button for two seconds.
A list (max. 10) will appear with stored material calibrations
L
(The materials with a * after their names are multi-point calibrations)
Select the desired material calibration with the selection arrow buttons and press “ENTER”.
If the material calibration is not in the list (because of max. 10 in the screen) fill in the first letter(s) of the
calibration name and press “ENTER”. A filtered list will now appear.
To go back to the main list fill in with blank spaces and press “ENTER”.
To clear the material description, fill in the spaces or select an empty material calibration out of the list and
press “ENTER”.
How can I delete a calibrated material?
For deleting one or more material calibrations see Section 7.10
To delete all Materials, select “Master Reset Material” in the CONFIGURATIONS menu and press
“ENTER”.
Test function
With the Test Function both units will feed material with the set feeding time and set/calculated speed.
Do a test as follows:
Go to PRODUCTION menu
Fill in the production settings
Use the arrow buttons to go to “Test”
Select “YES” and press “ENTER”
The unit will run with the set parameters.
To stop the test, press the “STOP” button.
PRODUCTION SETTINGS
Set speed: rpm
Dos.time : s
Test : NO/YES
PRODUCTION DATA
Speed : rpm
Time : sec
Status :
26 Dual Feed TrueFeed Manual