5.1 SCREEN SENSOR
A “Screen Sensor” can be connected to the Sentinel as shown in the “Generic Connection Diagram”. When this is
integrated the system detects a drop in the fog density in the protected area and will re-trigger the Sentinel to
maintain the fog level. When fitted the Screen Sensor is connected to the Hold-off input pins and, consequently, it
prevents the use of a hold-off detector.
NB: It is critical that the Screen Sensor is installed in an area that receives the maximum fog coverage. It will not
operate correctly if this is not achieved. (See 4.2 generic connection diagram).
5.2 ENERGY SAVING MODE (ESM)
When ESM is selected and the alarm panel input to the Smoke Screen is “Unset” the Smoke Screen lowers its
running temperature to a standby level to reduce power consumption and cost. When the Smoke Screen receives an
‘Alarm Set’ input it automatically heats to its normal operating temperature. If the Smoke Screen is in ESM mode and
is activated as soon as the alarm is set, ie before it has heated to normal operating temperature, it will still
produce smoke but possibly for a shorter period than the set smoke time.
5.3 SERVICE MODE
Setting dip switch No 4 (see diagram under “Circuit Board Layout”) to “On” puts the Smoke Screen into “Service
Mode”. This setting prevents the Smoke Screen from making smoke whilst work is conducted with power applied.
To highlight that the Smoke Screen is in “Service Mode” the Tamper output is put into an alarm state.
FAILURE TO DISABLE SERVICE MODE WHEN NO LONGER REQUIRED WILL PREVENT THE SMOKE SCREEN
OPERATING.
5.4 TURBO SMOKE MODE
When “Turbo Smoke Mode” is set (see section under “Programming”) the Smoke Screen produces a high-volume
burst of smoke to provide rapid obscuration of a local, high value protected area. In “Normal Smoke Mode” the
Smoke Screen produces a short full-output burst followed by a lower output over a longer period.