1.5 TYPICAL INSTALLATIONS
A typical installation can be configured in the following way:
The Smoke Screen is wall or ceiling mounted in the appropriate location.
A Hold-off PIR (or similar device) located within the same area as the Smoke Screen providing a confirmation
signal to the Smoke Screen to start, or re-start, ‘smoke’ production.
A Set command supplied by an alarm control panel, or equivalent, in the form of an N/C (normally closed) or
an N/O (normally open) relay changing state when the alarm system is set for operation.
A Trigger command supplied by the alarm control panel, or equivalent, in the form of an N/C (normally
closed) or an N/O (normally open) relay changing state when the alarm system confirms an intruder alert.