EasyManua.ls Logo

ConMed 7550 - Page 4

Default Icon
54 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Section Title Page
6.8 Single-Ended Amplifier [A9] ............................................................................. 6-16
6.9 RF Output Assembly/Component
s [A10] ......................................................... 6-17
6.10 Low Voltage Power Supply [A6] .......................................................................
6-18
6.11 HS/A.R.M. Assemb
ly [A11] ............................................................................. 6-18
6.11.1 Handsense Circuit ...........................................................................................................6-18
6.11.2 Aspen Return Monitor (A.R.M.) ....................................................................................
6-19
6.11.3 RF Leakage Monitor .......................................................................................................
6-20
6.11.4 Transformer Select Relays ................................................................................................
6-20
6.11.5 Arc Sense Transformer ....................................................................................................
6-20
7.0 Maintenance/Checkout ...................................................................... 7-1
7.1 Introduction ........................................................................................................ 7-1
7.2 Cleaning .............................................................................................................. 7-1
7.3 Generator & Mobile Storage Assembly ................................................................ 7-1
7.4 Access to Circuits & Factory Settings .................................................................. 7-2
7.5 Default Settings (Factory Settings) ...................................................................... 7-2
7.6 AC Mains Frequency & Voltage .......................................................................... 7-2
7.7 Initial Setup & Test ............................................................................................. 7-3
7.7.1 Accessory Connections ......................................................................................................7-3
7.7.2 Display Panel Testing ........................................................................................................7-3
7.7.3 Activation Testing .............................................................................................................7-5
7.7.4 RF Output Power Checks .................................................................................................7-5
7.7.5 Argon Flow Testing ..........................................................................................................7-6
7.7.6 Remote Power Control Testing .........................................................................................7-6
7.7.7 Return Monitor (A.R.M. - Aspen Return Monitor) ..........................................................7-7
7.8 Pulsed Cut Mode ................................................................................................. 7-8
7.9 RF Leakage Test .................................................................................................. 7-8
7.10 Final Checks ........................................................................................................ 7-8
7.11 Mobile Storage Pedestal (Cart) ............................................................................ 7-8
8.0 Calibration ........................................................................................ 8-1
8.1 Introduction ........................................................................................................ 8-1
8.2 Equipment List ...................................................................................................
8-1
8.2.1 Standard Equipment List ..................................................................................................8-1
8.2.2 Optional Calibration Equipment List ................................................................................
8-1
8.2.3 Test Leads & Adaptors ......................................................................................................
8-1
8.3 Calibration Set-Up .............................................................................................. 8-1
8.4 A.R.M. Calibration (HS/A.R.M. Assembly - A11) ............................................
8-1
8.4.1 10 Ohm A.R.M. Calibration .............................................................................................8-1
8.4.2 150 Ohm A.R.M. Calibration ...........................................................................................
8-2
8.5 High Voltage Calibration (HV/Flow Control Assembly - A1) ............................. 8-2
8.5.1 HV RAMP Calibration .....................................................................................................8-2
8.5.2 High Voltage Adjust .........................................................................................................
8-2
8.5.3 HV_MON Adjust .............................................................................................................
8-2
8.6 Argon Flow Calibration (HV/Flow Control Assembly - A1) ............................... 8-2
8.6.1 dP Calibration (Differential Pressure) ................................................................................8-2
8.6.2 PABS Calibration (Absolute Pressure) ...............................................................................
8-2
8.6.3 Flow Rate Calibration (Optional) .....................................................................................
8-2
8.6.4 FMON Calibration ...........................................................................................................
8-3
8.7 Power Calibration ................................................................................................ 8-3
8.7.1 Filter Calibration - Full Bridge Modes (Optional) .............................................................8-3
8.7.2 Cut Power Calibration (Power Control Assembly - A4) ....................................................
8-3

Table of Contents

Related product manuals