CS1171 Hand-Held Programmer User's Manual
Control Solutions LLC Page 36 of 56
A typical charging cycle will go through the following charging
modes in order:
1. Pre-charge,
2. Charge Qualification,
3. Bulk Charge,
4. Top-off Charge, and
5. Float.
The Fast chgled on/off setting determines when to flash the LED.
When set to On, flash will occur at the end of Bulk Charge mode.
When set to Off, flash will occur at the end of Top-off charge
mode.
When set to On, the system turns On and Off with a pushbutton or
momentary contact of the key switch. When set to Off, the unit
remains powered up only while the key switch remains closed, and
powers down when the key switch contact is opened.
When set to On, the unit will not power down immediately when
key switch state indicates power down, but remains on for the
duration defined by Timeout. When set to Off, the unit powers
down as normal with no delays.
Used to configure throttle for acceleration control, instead of speed
control. When set to Off, the controller interprets throttle as a
conventional speed adjustment, where the direction and speed of
the unit is determined by the displacement from center and the
magnitude of the displacement. When set to On, a throttle
displacement indicates acceleration to the controller. The unit
accelerates proportional to this displacement, as long as it is
present. Deceleration requires an equal and opposite
displacement. FWD/REV input controls direction while Accel drive
is On, which results in a hard stop when toggling direction.
When set to On, motor compensation (boost) is limited by the
absolute throttle position.
When set to On, motor compensation (boost) is limited by the
acceleration of the throttle position (change in throttle over time).
When set to On, negative (decelerating) boost is not applied,
resulting in a soft deceleration.
Depending on the module configuration quickstop can be wired as
active (+5 V) or passive (GND). In a passive configuration:
When the parameter is On, quickstop is asserted when active.
When the parameter is Off, quickstop is asserted when the
circuit is closed.