User's Manual CS1171 Hand-Held Programmer
Page 17 of 56 Control Solutions LLC
Using the Hand-Held Programmer
Follow the directions below to prepare and use the CS1171 HHP.
1. Insert one end of the interface cable into HHP's 8-pin jack (RJ45).
2. With the controller turned off, connect the other end of the cable to the controller's
programming port refer to the Wiring Configurations section for details on your
specific controller.
3. Turn on the Hand-Held Programmer by pressing the Power/Enter button, or by
turning on the Controller using the key switch.
4. If the HHP is compatible with the controller version, upon powering up the HHP, a
splash screen CS Programmer CS1171C OEM Vxxx (for the OEM version) or CS
Programmer CS1171R DLR Vxxx (for the Dealer version) is displayed for five
seconds, followed by the Main menu. If the controller generates a fault code, the first
menu item will be the controller’s fault code followed by FWD speed. If no fault code is
present, the first menu item is FWD speed. Powering up the controller with a fault
code will not inhibit HHP functionality.
5. To modify a parameter:
Step
Action
1
Scroll through the Main menu using + to scroll up, and to scroll
down, until the parameter you wish to change is reached
The parameter will blink when selected
2
Press > to select the parameter value
3
Press the + to increment/toggle the parameter or to
decrement/toggle the parameter value
4
Press < to save the value to the controller
Table 6 - Modifying a Parameter
As a parameter's value is modified, it is continuously updated to the controller so that
its effect can be verified immediately. If power is lost to the controller or the HHP
If the controller version is incompatible with the HHP version, the
HHP will display BAD REV! See user manual for three seconds,
and then the controller firmware version will be displayed FW rev h
xxx FW l xxx, and HHP functions will be disabled. (See
www.controls.com/index.php/support/troubleshoot/hhp for error
code explanations.)
You must have an 8-pin connector on your controller to be able to
use the HHP Power/Enter button for power-up.