M’Ax Advanced User Guide 20
Issue Number: 4 www.controltechniques.com
Figure 5-1 Menu 3 software diagram
Menu 2
2.01
Post-ramp
reference
Hard speed
reference
3.22
Hard speed
reference selector
3.23
Final speed
reference
SLM
Number of
encoder lines
3.55
3.02
Speed
f
eedback
Encoder simulation
Zero-speed
threshold
3
.05
A
t-speed
lower limit
3
.06
A
t-speed upper
limit
3
.07
O
ver-speed
threshold
3
.08
A
bsolute
a
t-speed detect
mode select
3
.09
10.03
At zero
speed
indicator
10.05
Below set
speed
indicator
10.06
At speed
indicator
10.07
Above set
speed
indicator
S
peed detection and limits
1
2
6
7
1
3
1
4
A
A\
B
B\
Z
Z\
SIM ENC
Demand
Feedback
S
LM PID
buffer 1
F/D mode
select
3.56
Speed detection
indicators
M
onitoring
3.28
Feedback-
encoder
r
evolution
counter
3.29
Feedback-
encoder position
3.32
Z marker pulse
r
eceived indicator
Alignment
Shaft-key offset
3.53
Z
ero offset
3.54
3.01
S
LM PID
buffer 2
S
LM PID
buffer 3
Sequencer
(Menu 6)
)
technology
Marker
pulse
13.01
Pulse
reference
Menu 13

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Control Techniques M'Ax and is the answer not in the manual?

Control Techniques M'Ax Specifications

General IconGeneral
ProtectionOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short Circuit
FeedbackResolver
Control ModesTorque, position
CommunicationCANopen
SafetySTO (Safe Torque Off), SS1 (Safe Stop 1)
Input Voltage200-240V AC, 380-480V AC, 525-690V AC
Operating Temperature0°C to 40°C
Storage Temperature70 °C
Humidity5 - 95% non-condensing
WeightVaries by model