May 2009 | Revision 6.0
5-2
CHAPTER 5.0 | TECHNICAL SPECIFICATIONS
Adaptis A1000
Tissue culture
230V/50Hz 120V/60Hz
Kit total inputs amp 2.83 5.4
Light average 200 200
Light average with highlight accessory 310 n/a
Number of fixtures 8 8
Cabniet total Input Amps 5.9 10.6
Total input amps 8.7 15.8
Minimum total circuit ampacity 9.4 17.4
Maximum overcurrent protection 15 20
Additional fixture 0.35 n/a
Adaptis A1000
Plant growth
230V/50Hz 120V/60Hz
Kit total inputs amp 2.5 4.6
Light average* 650 650
Light average with highlight accessory* n/a n/a
Number of fixtures 1 1
Cabniet total Input Amps 5.9 10.6
Total input amps 8.3 15.1
Minimum total circuit ampacity 9.1 16.8
Maximum overcurrent protection 15 20
Additional fixture n/a n/a
5.7 Design performance
Humidity max [Lights On/L Off] [%RH] 60/90 60/90 60/90 60/90
Humidity min [%RH] Ambient Ambient Ambient Ambient
Temperature max [ºC] 45 45 40 40
Temperature min [Lights ON] [ºC] 10 10 10 10
Temperature min [Lights Off] [ºC] 4 4 5 5
Temperature control [ºC] + / - 0.5 + / - 0.5 + / - 0.5 + / - 0.5
Humidity control [%RH] + / - 6 + / - 6 + / - 6 + / - 6