Connection diagram (floor-standing units)
The following illustration shows the wastewater connections to a size 12.20 combi oven as an exam‐
ple of all floor-standing units:
Item Name Function
1
Appliance drain On the appliance floor, con‐
nection point C, see 'Con‐
nection diagrams' on page
140
2
Safety overflow
On the appliance floor,
connection point M, see
'Connection diagrams' on
page 140
Used to drain away water
in the event of a fault
(blockage).
3
Drain pipe DN
50
Minimum internal diame‐
ter = 46 mm
Min. slope min. 3.5% (2°)
Drain options:
Fixed connection
Open tank
Gully
Connecting the appliance to the drain
Connect the appliance as shown in the connection diagram. For table-top units, use the flat bend sup‐
plied.
6 Installation
102