Convotherm 4 GS
6.10 6.20 10.10 10.20 12.20 20.10 20.20
1N~ 100V 50/60Hz
Rated power consumption [kW] 0.5 0.5 0.5 0.5 0.5 1.0 1.0
Convection power [kW] 0.1 0.1 0.1 0.1 0.1 0.2 0.2
Motor power [kW] 0.35 0.35 0.35 0.35 0.35 0.7 0.7
Rated current [A] 5.2 5.2 5.2 5.2 5.2 9.8 9.8
Fuse rating [A] 16 16 16 16 16 16 16
Recommended conductor
cross-section for wires laid un‐
covered in air up to 5 m in
length.
[mm
2
]
3G2.5 3G2.5 3G2.5 3G2.5 3G2.5 3G2.5 3G2.5
Recommended residual-current
device
Type
A A A A A A A
Optional residual-current device Type B/F B/F B/F B/F B/F B/F B/F
1N~ 230V 50/60Hz
Rated power consumption [kW] 0.6 0.6 0.6 0.6 0.6 1.1 1.1
Convection power [kW] 0.1 0.1 0.1 0.1 0.1 0.2 0.2
Motor power [kW] 0.35 0.35 0.35 0.35 0.35 0.7 0.7
Rated current [A] 2.3 2.3 2.3 2.3 2.3 4.3 4.3
Fuse rating [A] 16 16 16 16 16 16 16
Recommended conductor
cross-section for wires laid un‐
covered in air up to 5 m in
length.
[mm
2
]
3G2.5 3G2.5 3G2.5 3G2.5 3G2.5 3G2.5 3G2.5
Recommended residual-current
device
Type A A A A A A A
Optional residual-current device Type B/F B/F B/F B/F B/F B/F B/F
1N~120V 60Hz
Rated power consumption [kW] 0.5 0.5 0.5 0.5 0.5 1.0 1.0
Convection power [kW] 0.1 0.1 0.1 0.1 0.1 0.2 0.2
Motor power [kW] 0.4 0.4 0.4 0.4 0.4 0.7 0.7
Rated current [A] 4.7 4.7 4.7 4.7 4.7 8.9 8.9
Fuse rating [A] 16 16 16 16 16 16 16
Recommended conductor
cross-section for wires laid un‐
covered in air up to 5 m in
length.
[mm
2
]
3G2.5 3G2.5 3G2.5 3G2.5 3G2.5 3G2.5 3G2.5
Recommended residual-current
device
Type A A A A A A A
Optional residual-current device Type B/F B/F B/F B/F B/F B/F B/F
2~ 230 V 50/60Hz
Rated power consumption [kW] 0.5 0.5 0.5 0.5 0.5 1.0 1.0
Convection power [kW] 0.1 0.1 0.1 0.1 0.1 0.2 0.2
Motor power [kW] 0.35 0.35 0.35 0.35 0.35 0.7 0.7
Rated current [A] 2.3 2.3 2.3 2.3 2.3 4.3 4.3
Fuse rating [A] 16 16 16 16 16 16 16
Recommended conductor
cross-section for wires laid un‐
covered in air up to 5 m in
length.
[mm
2
]
3G2.5 3G2.5 3G2.5 3G2.5 3G2.5 3G2.5 3G2.5
9 Technical data