Safety hazard: gas
Danger Where or in what situations does the
hazard arise?
Preventive action
Explosion hazard from
gas
If the appliance is moved Never move appliance during use
For table-top units on a wheeled
platform and with a flexible connec‐
tion pipe:
■
Only move appliances forward for
the purpose of cleaning the case
of the combi ovens or the floor un‐
der the appliances. Do not move
appliances forward by more than
the distance permitted by the re‐
taining device on the wheeled plat‐
form (0.5 m max.).
■
Before operating the appliance, al‐
ways engage the parking brake on
the wheels
■
Check that wheel brakes are on
before operation each day
Risk of suffocation from
lack of breathable air
Where appliance is installed
■
Check the exhaust gas readings
and if they need adjusting get a
qualified gas installation engineer
from an authorized service compa‐
ny to adjust the burner
■
Ensure that a ventilation system is
in place, is working properly and is
running, and that the ventilation re‐
quirements stipulated by the gas
installation engineer are met
■
Do not obstruct lower area of
equipment
■
Only operate appliance in a
draught-free environment
Safety hazard: mechanical parts of the appliance
Danger Where or in what situations does the
hazard arise?
Preventive action
Risk of injuries from ro‐
tating fan
If the cooking chamber is being
cooled using 'Cool down' with the
appliance door open and the fan
wheel is exposed because the suc‐
tion panel is not fitted
Make sure that the suction panel is
fitted and secured in place
3 For your safety
32