Service manual OEB/OES/OGB/OGS
5_00e Troubleshooting list_L 7/27 2013-01-30
E
T
O
E
B
O
E
S
O
G
B
O
G
S
Error-
message
Error description possible cause or remedy
temperature
Only when 6 times in a
row over-temperature
is detected.
to be cooked)
ID 26
Core Temperature
Probe 2 – Over
temperature
Only when 6 times in a
row over-temperature
is detected.
CTC probe has temperature higher than the maximum
acceptable value (sensor not correctly inserted into the food
to be cooked)
ID27
Core Temperature
Probe 3 – over
temperature
Only when 6 times in a
row over-temperature
is detected.
CTC probe has temperature higher than the maximum
acceptable value (sensor not correctly inserted into the food
to be cooked)
ID28
Core Temperature
Probe 4 – Over
temperature
Only when 6 times in a
row over-temperature
is detected.
CTC probe has temperature higher than the maximum
acceptable value (sensor not correctly inserted into the food
to be cooked)
E13.xxx
ID 20
Steam generator
(B4 thermoelement)
Excessive
temperature (if
temperature
measured in the SG
>120°C
longer than 26 sec.)
Foaming in the steam generator when cooking (due to e.g.
wrong, non-original CONVOTHERM cleaning agents)
Calcification of the steam generator
Boiling dry of the immersion heaters due to double level
sensor’s short circuit to earth
E15.xxx
ID21
Condenser sensor
(B3- thermoelement)
excessive temperature
(if temperature in the
condenser measured
> 100°C longer than
26 sec.)
Water reservoir in the condenser too hot:
a) Water tap closed
b) Appliance connected to hot water
c) Solenoid valve “condenser cooling” defective
d) Coil from the solenoid “condenser cooling”
defective
e) Inlet filter in the solenoid valve contaminated
f) Quenching nozzle in the condenser/siphon
blocked
E16.xxx
ID38
Demoisturisation flap
operating fault
(only Mini)
Error will be generated
if after 30 sec. the
control no zero-
crossing at the
microswitch is
Demoisturisation flap faulty
a) Stiff
b) Motor contact
c) Motor defective
d) Flap blocked
e) Cable defects (contact / motor)