EasyManua.ls Logo

Convotherm OGS 6.10 - Page 177

Default Icon
285 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Service Handbook OEB/OES/OGB/OGS
AS/11-2011 6_16e_Problem case cloudy glass panels - glass corrosion_b
Prevention measures:
Page 2 / 2
Instructions – Check water supply:
Water softening systems are not suitable for combination oven steamers.
Reason: Water softening systems are regenerated with salt NaCl.
Remedy:
Install a partial desalinization cartridge.
Water must have a least over 5°dh; optimal is 7°dh.
Remedy:
Check the adjustments on the water preparation
system and if necessary re-adjust the system.
An on-site corrosion protection system that injects phosphate silicate products
is not recommendable on OES/OGS units.
Remedy:
Operate the units with water that isn’t prepared
with a corrosion protection system.
Instructions – Check cleaning methods:
Use only the original CONVOTHERM cleaners!
Thoroughly remove the cleaning solution after the cleaning process by rinsing
with a lot of clear water or using the Automatic Cleaning Programme if
available
!
Hinweis
Notice:
Inner Glass Panel Part Numbers for P3 units
OS/OB 6.10: 2514388 OS/OB 6.20: 2514389
OS/OB 10.10: 2514390 OS/OB 10.20: 2514391
OS/OB 12.20: 2514392 OS/OB 20.10: 2514393
OS/OB 20.20: 2514394

Table of Contents

Other manuals for Convotherm OGS 6.10

Related product manuals