Service manual OEB/OES/OGB/OGS
KD / 31.03.2009 5_00d_Fehlersuchliste_h_En.doc
Page 9 / 21
easy
touch
OEB OES OGB OGS
Error
message
Error description
Possible cause or remedy
E29.0 Short circuit to earth
of a thermoelement
A thermoelement sensor has contact with appliance
housing
Connection between sensor wire and sensor housing
Test individual sensors for short circuit to earth
(beginning with CTS)
E29.1
ID=15
CTS1 short circuit to
earth
Thermoelement sensor B10 has contact with
appliance housing
Possible cause:
a) Sensor wiring broken
b) Water has entered measuring tube
c) Thermoelement defective.
E29.2
ID=16
CTS2 short circuit to
earth
Thermoelement sensor B10 has contact with
appliance housing
Possible cause:
a) Sensor wiring broken
b) Water has entered measuring tube
c) Thermoelement defective.
E29.3
ID=17
CTS3 short circuit to
earth
Thermoelement sensor B10 has contact with
appliance housing
Possible cause:
a) Sensor wiring broken
b) Water has entered measuring tube
c) Thermoelement defective.
E29.4
ID=18
CTS4 short circuit to
earth
Thermoelement sensor B10 has contact with
appliance housing
Possible cause:
a) Sensor wiring broken
b) Water has entered measuring tube
c) Thermoelement defective.
E33.0 Steam generator
operating fault (No
temperature increase
in the SG within
3 mins. by >5°C on
the B3 sensor)
Immersion heater defective
Heater contactor defective
Calcified B3 sensor
E34.0 SG pump error
Pump does not start
(double level sensor
does not reach
lower level within 20
secs.)
Pump defective (M4)
Pump blocked / contaminated
Water level sensor has short circuit to earth due to
calcification
Filling gap of the area touching the water is calcified
together with the double level sensor
E80.0 ID error (identity
error)
It cannot be determined whether the appliance is gas
or electric, therefore all outputs are switched off.
IDM module defective