Mini-world service manual
KD / 31.03.2009 5_00d_Fehlersuchliste_Mini_f_EN.doc
Page 2 / 9
Error
message
Error description
Possible cause or remedy
ST
5020
ST
7000
easy
touch
E11.0
ID=23
Oven sensor (B6
thermoelement)
excessive
temperature
(temperature on
the sensor
>300°C)
Hot air contactor does not switch off (burnt together)
E12.1
ID=25
Core
temperature
sensor 1 -
excessive
temperature
Temperature of CTS sensor already higher than the maximum
possible desired value (sensor not inserted into food correctly)
E12.2
ID=26
Core
temperature
sensor 2 -
excessive
temperature
Temperature of CTS sensor already higher than the maximum
possible desired value (sensor not inserted into food correctly)
E12.3
ID=27
Core
temperature
sensor 3 -
excessive
temperature
Temperature of CTS sensor already higher than the maximum
possible desired value (sensor not inserted into food correctly)
E12.4
ID=28
Core
temperature
sensor 4 -
excessive
temperature
Temperature of CTS sensor already higher than the maximum
possible desired value (sensor not inserted into food correctly)
E15.0
ID=21
Condenser
sensor (B3-
thermoelement)
excessive
temperature
(
if temperature in
the condenser
measured > 100°C)
Water reservoir in the condenser too hot:
a) Tap closed
b) Appliance connected to hot water
c) Solenoid valve “condenser cooling” defective
d) Coil from the solenoid “condenser cooling” defective
e) Inlet filter in the solenoid valve contaminated
f) Quenching nozzle in the condenser/siphon blocked
E16 Demoisturisation
flap operating
fault
Demoisturisation flap faulty
a) Stiff
b) Motor contact
c) Motor defective
d) Flap blocked
e) Cable defects (contact / motor)
f) Microswitch defective
g) Microswitch not correctly adjusted
h) Motor shaft spins idle
E21.0
ID=5
Oven sensor
(B6-
thermoelement)
interruption
Sensor wiring interrupted (plug X16 of the control module)
Oven sensor (B6) interrupted (defective)