21
About the User Types
The following user types are available.
(Press the key shown next to the type name
to select a type directly, or use | or ¬.)
Manager 1
Users of this type have access to all user
menus and options. They can set and
unset assigned wards from any keypad. By
default, user 001 is set up as a manager,
with a default user code of 5678 (567800
when using six-digit codes).
Standard Global 2
Users of this type have access to User
Menu 1, options 0, 1, 2, 3, 4, 5, 8 and 9.
They can set and unset assigned wards
from any keypad.
Standard Ward 3
Users of this type have access to User Menu
1, options 0, 1, 2, 3, 4, 5, 8 and 9. They can
only set and unset assigned wards from a
keypad assigned to the wards being set or
unset, e.g. if a user is assigned to wards 1
and 2, and uses a keypad assigned to
ward 2 only, the user can set or unset ward
2 only.
Prox Tag User 4
Users of this type present a proximity tag to
the keypad instead of entering a user
code. They have access to User Menu 1,
options 0, 1, 2, 3, 4, 5, 8 and 9. They can
set and unset assigned wards from any
keypad. When unsetting, all associated
wards are unset (regardless of any
programmed auto-unset wards) and the
keypad displays no options.
Z
User01 cannot be a prox tag user.