English
Ice cream freezer
6
3TECHNICAL DATA
3.1 Technical data plate and CE marking
The technical data and CE mark plate must not be removed. It is positioned on the machine's rear side and shows:
— manufacturer's name and address [F];
— model's denomination [MOD] and serial number [S/N];
— types [GAS] and quantities [gr] of refrigerating gases included;
— year of manufacturing [ANNO];
— tension [V], frequency [Hz] and number of phases [Ph], electrical input power [kW] and current [A];
— CE mark.
— the symbol for the dismantling of the product [G].
3.2 Acoustic pressure level
The average equivalent continuous acoustic pressure level of this machine is quoted in the Technical Handbook (Technical
Data section). This data has been measured at 1 meter from the surface of the machine and at 1.60 meters from ground-
level, during the machine’s functioning.
4CARRYING AND UNPACKING
Note: We suggest you to let the Assistance Service or qualified technicians carry out the transportation, un-
packing and installation.
TO LIFT THE MACHINE ALWAYS USE AN ADEQUATE LIFTING
DEVICE
. ATTEMPTING TO LIFT IT MANUALLY IS DANGEROUS
AND CAN DAMAGE YOUR HEALTH.
The machine’s weight specifications, both inclusive of packaging and net, can be
found in both the supplied documents and on the packaging itself.
To prevent the oil contained in the compressor to flow into the refrigerating circuit, it is neces-
sary to always keep the machine in upright position, both during carrying and during the instal-
lation and operation. Always follow the instructions on the packing.