112 EM 9250 Operator’s manual
- press the key to confirm and exit.
Activation of the second operator is indicated by the illumination of the LED on the
display panel.
Repeat the procedure described above to return to the first operator.
14. WHEEL SPIN COUNTER
This programme is used to display the total number of spins performed by the machine
since its first start-up (tot SPi), the number of spins performed since the last unbalance
calibration (CAL SPi) and the number of partial spins performed since the machine was
last started (PAr SPi).
Proceed as follows to recall this programme:
•pressthe key
•usethe keys to search for -SP in-
•pressthe key to display the total number of spins performed by the machine
since its first start-up (tot SPi)
•pressthe key to display the number of spins performed since the last sensitivity
calibration (CAL SPi). It is reset at each new calibration
•pressthe key to display the number of spins performed since the last sensitivity
calibration (PAr SPi). It is reset each time it is turned off
•pressthe key to exit.
15. GENERAL CONFIGURATIONS - SET UP
The machine can be configured according to your requirements. The following configura-
tions are available:
- Selecting vehicle type (car – motorcycle)
- Selecting the mode for acquiring wheel dimensions in the ALU1 and ALU2 balancing
programmes (ONLY the version with manual sensor)