IDC 2XX Service Manual
Publication Number: 621057403SER - 14 - © 2007-2019, Cornelius Inc.
4.
BOTTOM
PLATE P/N
1903
O
F
F
SNAP FIT CLIP
REAR
TAB
SNAP FIT
CLIP
INNER
NOZZLE
NOZZLE
SNAP FIT
CLIP
SNAP FIT
CLIP
Return the inner nozzle to the nozzle and replace the assembly to the valve.
MONTHLY
Clean and sanitize the hopper interior and beverage system, if applicable (see CLEANING INSTRUCTIONS).
BEVERAGE SYSTEM (IF APPLICABLE)
WARNING: Disconnect Power Before Cleaning! Do no use metal scrapers, sharp objects, or
abrasives on the ice storage hopper, top cover and the
agitator disk, as damage may result. Do not
use solvents or other cleaning agents, as they may attack the plastic material.
• Soap solution – Use a mixture of mild detergent and warm (100
o
F) potable water.
• Sanitizing solution – Dissolve 2 packets (4 oz.) Stera Sheen Green Label into 2 gallons of warm (80-
10
0
o
F) water to ensure 200 ppm of available chlorine.
• Cleaning tank – Fill clean, empty tank with a mixture of
mild detergent and five (5) gallons of warm
potable water (120
o
F).
CAUTION: When pouring liquid into the hopper, do not exceed the rate of 1/2 gallon per minute.
Cold Plate
1. Remove splash panel.
2. Remove or move the plastic cold plate cover to expose the cold plate.
3. Locate and remove any debris from the drain trough. Check that the drain holes are not clogged.
4. Pour small amount of soap solution through cold plate openings in hopper.
5. Using a cloth, wash down the surfaces of the cold
plate and plastic cover with soap solution.
6. Install and properly position the access covers on
the cold plate.
7. Install the splash panel in the reverse order it was removed.
8. Rinse cold plate surface by pouring potable water through hopper openings.
Sanitize syrup lines, B–I–B Systems
1. Remove all the quick disconnects from all the B–I–B containers.
2. Fill a suitable pail or bucket w
ith soap solution.
3. Submerge all disconnects (gas and liquid) in the soap solution and then clean them using a nylon
b
ristle brush. (Do not use a wire brush). Rinse with clean water.
4. Using a plastic pail, prepare approximately five (5
) gallons of sanitizing solution.