IDC 2XX Service Manual
Publication Number: 621057403SER - 24 - © 2007-2019, Cornelius Inc.
TROUBLESHOOTING
Beverage Not
BEVERAGE NOT DISPENSING
Is the key switch
on/off?
Check the key switch.
Off
Is
there power on
the line side of the
transformer?
On
1. Check the transformer
connections to the E-Board in
the E-Box.
2. Check the E - Board in the E-
Box ensuring that power is
being supplied to the board.
No
Is
there power on the
load side of the
transformer?
Yes
1. Check the transformer.
2. Change the transformer.
No
1.Check the wire harness from the
beverage valves to the terminal
board.
2. Check the beverage dispense valve
to ensure that they are functioning.
3. Change beverage valve.
4. Check the water line to the valve
and the syrup line to the valve.
Yes
Dispensing