IDC 2XX Service Manual
© 2007-2019, Cornelius Inc. - 25 - Publication Number: 621057403SER
Flat Drinks
FLAT DRINK(S)
Is the
drink temperature
above 40 degrees
Fahrenheit?
No
Is there
ice on the cold
plate?
Yes
Is CO2
being supplied to
the carbonator
tank?
1. Check CO2 supply tank.
2. Check CO2 supply lines.
3. Change CO2 tank.
No
1. Fill the hopper with ice.
2. Dispense some ice to
ensure that the agitator
spreads ice on the cold
plate.
No
Check ice coverage on
the cold plate.
Yes
Is the
CO2 pressure in
the system
correct?
Yes
Adjust CO2 pressure
accordingly.
No
Does
the carbonator
cycle when a 20oz
drink is
dispensed?
Yes
Refer to carbonator
flow chart.
Replace
carbonator pump.
Yes
No