Brush the bottom of the water pump
Brush the plastic parts around the evaporator
Brush evaporator
Brush water tank
Flush the evaporator
Rinse the sprinkler pipe and core rod
9. Take out the soaked parts and rinse them
with clean water (rinse 5 times).
14.2 Disinfection process
1. Mix 8 warming water (45~50℃) and 2
packages of disinfectant (KAY5, 28.4/package)
into a disinfectant (the amount of
disinfectant is adjusted according to the
amount of parts that need to be cleaned).
2. Soak the cleaned parts in the prepared
disinfectant.
While soaking the parts, use a spray can to
evenly and completely spray the disinfectant
on the surface of the parts that are in contact
with the ice, such as the evaporator ice tray,
ice shield, ice storage bucket, etc. (the dead
corners can be wetted with disinfectant
Disposable chopsticks wrapped in a rag to
clean)
After 20 minutes, take out the soaked parts and
rinse the sterilized parts with clean water.
Install the removed parts back to their
original positions (refer to 15.3 Parts
removal/installation process for
installation methods) and perform this step
strictly as required.
3. Use 1 liter of water and 1/2 package of
disinfectant (KAY5, 28.4/package) to make a
disinfectant.