EasyManuals Logo

Coway CHP-671R/L User Manual

Coway CHP-671R/L
74 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #46 background imageLoading...
Page #46 background image
Fault diagnosis
4-14
Coway co., Ltd
Function Explanation
4.
Compressor
operation
delay time
function
• Thecompressorstarts5minutesafterthepointatwhichCOOLselectionmode
was ON.
• IfthepoweristurnedONagainafterbeingstoppedwhiletheCOOLselection
mode was ON, the compressor starts after 5 minutes.
• Ifitisrestoredandoperatesnormallyafteracoldwatertemperaturesensorerror
or overcooling while the COOL selection mode is ON, the compressor starts 5
minutes after it had stopped.
5.
Cooling delay
safety blocking
function
• Thecoolingdelaysafetyblockingfunctionoperatesasfollows.
- If the compressor operates continuously for 150 minutes, its output is turned
OFF for 5 minutes regardless of cold water temperature to prevent overcooling
or ice formation.
- After the compressor's output is OFF for 5 minutes, it restarts according to cold
water temperature.
- If6.5°Corlessisdetectedwhilethecompressorhasoperatedfor130minutes
or more, output is stopped.
• Afterthecompressor'soutputisOFFfor5minutes,itrestartsaccordingtocold
water temperature control specifications.
- When the cold water temperature control specifications are ON temperature
(7.8°C)ormore,thecompressorstarts.
- If the cold water temperature control specifications are between ON temperature
(7.8°C)andOFFtemperature(5.7°C),thecompressordoesnotstart.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Coway CHP-671R/L and is the answer not in the manual?

Coway CHP-671R/L Specifications

General IconGeneral
BrandCoway
ModelCHP-671R/L
CategoryWater Filtration Systems
LanguageEnglish

Related product manuals