EasyManua.ls Logo

Coway CHP-671R/L - Major Part Characteristics

Coway CHP-671R/L
74 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Product characteristics and specifications
1-2
Coway co., Ltd
1-1-1 Major Part Characteristics
Part Name FEED valve / NOS valve (for safety cutoff)
Use Source water entry and safety cutoff function
Operation
principles
Opens and closes the flow path when full water signals from the low water level/full
water level sensor and overflow sensor are detected to stop entry of source water
in two ways.
Part Name Low water level / Medium water level / Full water level sensor (capacitance sensor)
Use Water level detection in the room-temperature water tank
Operation
principles
Detects the room-temperature water tank level in three stages and adjusts room-
temperature water operation through the FEED valve.
Part Name Overflow sensor (capacitance sensor)
Use Water level detection in the room-temperature water tank
Operation
principles
Operates the NOS valve to cut off room-temperature water when the water
overflow sensor detects an overflow in the room-temperature water tank.
Major Part Characteristics
Parts Standard ratings and specifications Remarks
Feed Valve / NOS Valve
• Volts:DC24V
• AMPS:210mA
Compressor • Refertotheratingplate.