Function Explanation
1.
Temperature
LEVEL setting
function
• EachtimetheCOOLselectionswitchispressed(1000msormore),changesinthe
orderofC1/C2/C3→C1/C2→C1→C1/C2/C3.
Compressor control temperature according to temperature LEVEL is as follows.
COOL LEVEL Compressor OFF Compressor ON Remarks
C1/C2/C3
flashing
5.7°C(123.045kΩ)
+20minutesdelayed
operation
7.8°C(111.344kΩ)
Stage 3
[Korean
temperature]
C1/C2 flashing
7.0°C(115.647kΩ)
+20minutesdelayed
operation
9.5°C(102.786kΩ) Stage 2
C1 flashing
9.0°C(105.224kΩ)
+20minutesdelayed
operation
11.5°C(93.649kΩ) Stage 1
• EachtimethetemperatureLEVELchanges,thesetmodeisimmediatelysaved.
• IfpoweristurnedOFFandthenONagain,theheaterandcompressorare
controlled according to the set temperature of the saved temperature LEVEL.
• IfthetemperatureLEVELsettingmodeisenteredafterthetemperatureLEVELis
changed, the saved temperature LEVEL is displayed.
• If15secondselapsesafterthetemperatureLEVELsettingfunctionoperates,the
temperature LEVEL setting function is canceled and normal mode is entered.
Each time the key is pressed, there is an additional 15 second delay.