6
MODEL
NO
HP VOLT PH Hz
RPM
(Nom)
NEMA
START
CODE
FULL
LOAD
AMPS
1.2 SERVICE
FACTOR
AMPS
LOCKED
ROTOR
AMPS
CORD
P/N
CORD
SIZE
CORD
O.D.
WINDING
RESISTANCE
MAIN - - START
3SCMPA Pump
3SCMPA30N4 3.0
208
3 60 1750 K
9.7 11.4
58.2 / 65.8 125496
12/4 - 18/4 .86 ± .02
1.08
230 9.2 10.6 1.08
460 4.6 5.3 32.9 125497 4.32
3SCMPA3054 3.0 575 3 60 1750 N 4.5 4.9 37.0 125497 12/4 - 18/4 .86 ± .02 4.32
3SCMPA50N4 5.0
208
3 60 1750 J
15.8 18.7
82.4 / 92.4 125496
12/4 - 18/4 .86 ± .02
0.72
230 15.0 17.2 0.72
460 7.5 8.6 46.2 125497 2.88
3SCMPA5054 5.0 575 3 60 1750 J 6.0 6.9 37.0 125497 12/4 - 18/4 .86 ± .02 4.32
3SCMPA75N4 7.5
208
3 60 1750 H
23.8 28.5
105.9 / 123.6 125496
12/4 - 18/4 .86 ± .02
0.43
230 23.7 27.2 0.43
460 11.9 13.6 61.8 125497 1.72
3SCMPA7554 7.5 575 3 60 1750 H 9.5 10.9 49.4 125497 12/4 - 18/4 .86 ± .02 2.69
Moisture and Temperature sensor leads are integral to power cord.
Winding Resistance ± 7.5% Winding resistance measured in OHMS @ 25°C (Between Lines) at motor leads.
Pump rated for operation at ± 10% voltage at motor.
▲ Cord Sufx: XC - 30 Feet, XF - 50 Feet, XJ - 75 Feet, or XL - 100 Feet
Cord sold separately.
Single Phase pumps require start components to be included in panel. Provided with pump.
CHART ‘A

Related product manuals