29 AirMedia® Series 3 Receivers Product Manual Doc. 9020C
l
Select Business Hours + Occupancy Based to apply the following behavior:
o
The display device is on and the receiver is awake during business hours. Define
business hours using the table:
n
Enabled: Turn the toggle on to include the day in the business hours schedule.
n
On Time: Enter the time of day (in 24-hour format) when business hours
begin.
n
Off time: Enter the time of day (in 24-hour format) when business hours end.
NOTE: When the On Time and Off Time settings are set to 00:00 and 23:59
respectively, the display device is on and the receiver is awake all day.
o
The touch screen is always on.
o
Crestron Fusion power events are ignored.
o
If room occupancy or vacancy is detected outside of business hours, the receiver
wakes up or goes to sleep accordingly.
o
Virtual button power events are allowed.
o
If an HDMI sync is detected outside of business hours, the receiver wakes up.
l
Select Based on Occupancy to apply the following behavior:
o
The connected occupancy sensor determines when the room is occupied or vacant.
o
If room vacancy is detected, the receiver goes to sleep.
o
If room occupancy is detected, the receiver wakes up.
o
If the display device is configured as a controlled display device, it powers on when
the room is occupied and powers off when the room is vacant.
o
The touch screen is on when the room is occupied and off when the room is vacant.
o
Crestron Fusion power events are permitted.
o
If an HDMI sync is detected, the receiver wakes up.
o
An AirMedia connection does not wake the receiver.