infiNET EX™ Thermostat Crestron CHV-TSTATEX
Setup
Identity Code
Every CHV-TSTATEX communicating via RF with a Crestron control system
through a CEN-RFGW-EX wireless gateway requires a unique RF ID. The RF ID is
a two-digit hexadecimal number that can range from 03 to FF. The RF ID of the unit,
set using Crestron Toolbox™, must match the RF ID specified in the SIMPL
Windows program.
Supplied Hardware
The hardware supplied with the CHV-TSTATEX is listed in the following table.
Supplied Hardware for the CHV-TSTATEX
DESCRIPTION PART
NUMBER
QUANTITY
Screws, Zinc, Phillips, Pan Head, #06-32 x 1” 2007251 2
Batteries, AA, Alkaline 2001050 2
Installation
NOTE: Installers should have a strong working knowledge of HVAC systems.
The location of the thermostat can affect its performance and efficiency. Install the
thermostat away from direct sunlight, drafts, doorways, skylights and windows. Also
make sure the thermostat is conveniently located for control access and setup.
Thermostats should be mounted 60 inches (1.6 meters) above the finished floor
(HVAC industry standard). Do not mount on an exterior wall.
The following tools/hardware are required for installation.
• Standard single-gang electrical box, mounted horizontally (not supplied)
• Phillips screwdriver (not supplied)
• Two 1-inch pan head Phillips screws (supplied)
• Two AA batteries (supplied)
Use the following procedure to install the CHV-TSTATEX in a standard,
single-gang electrical box (refer to illustration on the following page):
1. Separate thermostat front plate from back plate (you may need to exert force
when removing the front plate).
2. Turn HVAC system power OFF.
3. Feed HVAC wiring from the electrical box through the hole in the center of
the back plate so it can be connected to the proper terminals on the
CHV-TSTATEX after the thermostat is mounted.
4. Make sure unit is correctly oriented and place it in the electrical box.
8 • infiNET EX™ Thermostat: CHV-TSTATEX Operations & Installation Guide – DOC. 6989A