4 DM-NVX-E30(C)/DM-NVX-D30(C) Encoders/Decoders Product Manual DOC. 8425A
Rear Panel, DM-NVX-E30 and DM-NVX-D30
The following illustration shows the rear panel of the DM-NVX-E30 and DM-NVX-D30.
DM-NVX-E30 and DM-NVX-D30 Rear Panel
PWR: Bicolor green/amber LED, indicates operating power supplied via the power
pack (sold separately), PoE+ compliant Ethernet switch, or injector/PSE;
Lights amber while booting and green when operating
SETUP: Push button for on-screen display of IP address;
Red LED, indicates that the SETUP button is pressed and times out automatically.
NOTES:
If the DM-NVX-D30 decoder is connected to a DM-NVX-E30(C) or
DM-NVX-35x(C) encoder, pressing the
SETUP button on the DM-NVX-D30
for less than 10 seconds displays the decoder and encoder IP addresses.
The IP addresses are shown on the display connected to the HDMI output of
the decoder.
If the DM-NVX-E30 encoder is connected to a DM-NVX-D30(C) decoder, pressing
the
SETUP button on the DM-NVX-E30 for less than 10 seconds displays the
encoder and decoder IP addresses. The IP addresses are shown on the display
connected to the HDMI output of the decoder.
If the DM-NVX-E30 encoder is connected to a DM-NVX-35x(C) decoder,
pressing the
SETUP button on the DM-NVX-E30 displays the IP address of the
decoder only. The IP address is shown on the display connected to the HDMI
output of the decoder.
RESET: Recessed push button for hardware reset
IR 12: 4-pin 3.5 mm detachable terminal block;
Comprises two IR/serial ports
IR output up to 1.1 MHz;
1-way serial TTL/RS-232 (05 volts) up to 19200 baud;
Crestron IRP2 emitter sold separately
COM: 5-pin 3.5 mm detachable terminal block;
Bidirectional RS-232 port;*
Up to 115.2k baud, hardware and software handshaking support
Device control via RS-232 and IR requires the use of a Crestron 3-Series or later control system.