CTC Union IMC-1000C - Environmental and Certification Standards; Reliability Metrics (MTBF)

CTC Union IMC-1000C
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7
Environmental
Operating Temperature: -10°C~60°CIMC-1000C, IMC-1000CS;
-20°C~75°CIMC-1000C-E, IMC-1000CS-E
Storage Temperature: -40°C~85°C
Humidity: 5%~95% (Non-condensing)
Certifications
EMC: CE
EMI (Electromagnetic Interference): FCC Part 15 Subpart B Class A, CE
Railway Traffic: EN50121-4
Immunity for Heavy Industrial Environment: EN61000-6-2
Emission for Heavy Industrial Environment: EN61000-6-4
EMS (Electromagnetic Susceptibility) Protection Level:
EN61000-4-2 (ESD) Level 3, Criteria B
EN61000-4-3 (RS) Level 3, Criteria A
EN61000-4-4 (Burst) Level 3, Criteria A
EN61000-4-5 (Surge) Level 3, Criteria B
EN61000-4-6 (CS) Level 3, Criteria A
EN61000-4-8 (PFMF, Magnetic Field) Field Strength: 300A/m,
Criteria A
Shock: IEC 60068-2-27
Freefall: IEC 60068-2-32
Vibration: IEC 60068-2-6
MTBF (MIL-HDBK-217)
1,511,224 hoursIMC-1000C(-E)
1,789,658 hoursIMC-1000CS(-E)