9
9. ALARMS
Alarm
Display MyPool pH
Display MyPool ORP
Actions to do
Level
- Restore Product tank
Measure out of
range
(<5 pH)
(>9pH)
(<100 mV)
- Replace or check the
measure probe
- Restore pH / ORP measure
OFA Alarm
(time >OFA time)
- Push to reset
Flow Rate
- Restore Flow Rate
Calibration
Function
- Restore Probe or Buffer
solution and repeat
calibration procedure
System Error
- Press to restore Default
parameter
- Broken Unit
Modbus Error
- Press to reset
- Restore communication
Default Parameters
MyPool pH
MyPool ORP
Language
ES
Time OFA
OFF
Flow Input
OFF
Set Point value
7.4 pH
700 mV
Calibration
7 pH / 9 pH (2-point)
475 mV
Dosing Method
Acid
Low
To restore the default parameters, follow the steps below:
Power off the MyPool unit
Keep and pressed and power on the unit
The unit will flash
Press
Press to restore the default parameters.