EasyManuals Logo
Home>Curtis Instruments>Controller>1212P

Curtis Instruments 1212P User Manual

Default Icon
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #19 background imageLoading...
Page #19 background image
3 — PROGRAMMABLE PARAMETERS
pg. 15
Return to TOC 1212 & 1212P Manual - Sep 2019
DRIVE MENU
PARAMETER ALLOWABLE RANGE DESCRIPTION
Accel Max Speed 0.2–8.0 s Sets the rate (in seconds) at which the speed command increases when
throttle is applied with the speed limit pot is in its maximum speed position,
and the vehicle is traveling forward. Larger values represent slower response.
Note: Allowable range is restricted by the Accel Min Speed setting.
Accel Min Speed 0.2–8.0 s Sets the rate (in seconds) at which the speed command increases when
throttle is applied while the speed limit pot is in its minimum speed position,
and the vehicle is traveling forward. Larger values represent slower response
Note: Allowable range is restricted by the Accel Max Speed setting.
Decel High Speed 0.2–8.0 s Sets the rate (in seconds) that is used to slow down the vehicle when it
is traveling forward at high speed and throttle is reduced. Larger values
represent slower response.
Note: Allowable range is restricted by the Decel Low Speed setting.
Decel Low Speed 0.2–8.0 s Sets the rate (in seconds) that is used to slow down the vehicle when it
is traveling forward at low speed and throttle is reduced. Larger values
represent slower response.
Note: Allowable range is restricted by the Decel High Speed setting.
Rev Accel Max Speed 0.2–8.0 s Sets the rate (in seconds) at which the speed command increases when
throttle is applied while the speed limit pot is in its maximum speed position,
and the vehicle is traveling in reverse. Larger values represent slower
response.
Note: Allowable range is restricted by Rev Accel Min Speed setting.
Rev Accel Min Speed 0.2–8.0 s Sets the rate (in seconds) at which the speed command increases when
throttle is applied while the speed limit pot is in its minimum speed position,
and the vehicle is traveling in reverse. Larger values represent slower
response.
Note: Allowable range is restricted by Rev Accel Max Speed setting.
Rev Decel High Speed 0.2–8.0 s Sets the rate (in seconds) that is used to slow down the vehicle when it is
traveling in reverse at high speed and throttle is reduced. Larger values
represent slower response.
Note: Allowable range is restricted by Rev Decel Low Speed setting.
Rev Decel Low Speed 0.2–8.0 s Sets the rate (in seconds) that is used to slow down the vehicle when it
is traveling in reverse at low speed and throttle is reduced. Larger values
represent slower response.
Note: Allowable range is restricted by Rev Decel High Speed setting.
Key Off Decel 0.2–4.0 s Sets the rate (in seconds) that is used to slow down the vehicle at key-off or
in the event of a major fault.
E Stop Decel 0.2–4.0 s Sets the rate (in seconds) that is used to slow down the vehicle during
emergency reverse, i.e., when a throttle command >80% in the reverse
direction is given while the vehicle is moving forward. This gives the operator
a way to stop more quickly when unexpected conditions arise.
E Stop Pause 0.0–1.0 s Sets a pause before reversing direction after an emergency reverse stop.
This gives the operator time to return the throttle to neutral without moving
backwards.
Soft Start 0–100 % This parameter can be used to soften the bump associated with gear slack
in the transaxle when throttle is applied from the neutral state. Larger values
provide a softer slack take-up.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Curtis Instruments 1212P and is the answer not in the manual?

Curtis Instruments 1212P Specifications

General IconGeneral
BrandCurtis Instruments
Model1212P
CategoryController
LanguageEnglish

Related product manuals