20
Curtis 1212S Manual, R ev. B
3 — PROGRAMMABLE PARAMETERS: Emergency Reverse Parameters
EMERGENCY REVERSE MENU
ALLOWABLE
PARAMETER RANGE DESCRIPTION
Speed 10–100% Denesthemaximumreversespeedofthemotorwhenemergency
reverse is active.
Time Limit 0–10s Deneshowlongemergencyreverseisallowedtobeactiveafter
the vehicle is moving in reverse direction. Setting this parameter to zero
means there is no time limit.
Decel Rate 0.2 – 4.0 s Sets the rate at which the vehicle brakes to a stop when emergency
reverse is activated and the vehicle is moving forward. If the vehicle is
already moving in the reverse direction above the programmed EMR
speed, the vehicle will be brought down to the EMR speed.
Accel Rate 0.2 – 8.0 s Sets the rate at which the vehicle sccelerates in the reverse direction
when emergency reverse is activated.
Max Braking Current 15–90A Denesthemaximumallowedmotorcurrentwhenthevehiclebrakes
to a stop when emergency reverse is activated.
Switch Normally Closed On,Off Denestheemergencyreverseswitch(bellybuttonswitch)type.
On = BB switch is normally closed when it is not pressed.
Off = BB switch is normally open when it is not pressed.
EMR Interlock On , Off Enables the emergency reverse interlock feature.
On = the controller forces the throttle command to zero after
emergency reverse is activated until the interlock
switch is cycled.
Off = this feature is not enabled.