EasyManua.ls Logo

Curtis 1212S - 4 Monitor Menu

Curtis 1212S
47 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
22
Curtis 1212S Manual, R ev. B
4 — MONITOR MENU
4
MONITOR MENU
Through its Monitor menu, the 1313/1314 programmers provide access to
real-time data during vehicle operation. This information is helpful during diag-
nostics and troubleshooting, and also while adjusting programmable parameters.
MONITOR MENU
DISPLAY
VARIABLE RANGE DESCRIPTION
Temp -55–+127°C Controller’sinternaltemperature.
Battery Voltage model specic Battery voltage.
1212S-2xxx: 0.0 38.2 V
1212S-3xxx: 0.0 55.0 V
Motor Voltage model specic Voltage drop between the motor terminals.
1212S-2xxx: -27.4 +27.4 V
1212S-3xxx: -41.1 +41.1 V
Motor Thermal Cutback 0–100 % Current cutback during motor overtemperature,
as a percentage of max current.
100% = no cutback.
Armature Current -100 – +100 A Measured motor armature current.
Current Limit 0–100 A Ultimate current limit of the controller, taking
into account boost mode, thermal protection,
etc.
Resistance 0–854 m
Ω Measured system resistance, when the
motor is stalled.
Throttle 0–100 % Available throttle input.
Mode Input On , Off Status of the mode switch (at J1-4).
Forward Input On , Off Status of the forward switch (at J1-10).
Reverse Input On , Off Status of the reverse switch (at J1-12).
Interlock Input On , Off Status of the interlock input switch (at J1-6).
EMR Input On , Off Status of the emergency reverse switch
(belly button switch, at J1-14).
Lift Lockout Input On , Off Status of the lift lockout input signal from
Curtis 906 (at J1-9).

Related product manuals