22
Curtis 1212S Manual, R ev. B
4 — MONITOR MENU
4
MONITOR MENU
Through its Monitor menu, the 1313/1314 programmers provide access to
real-time data during vehicle operation. This information is helpful during diag-
nostics and troubleshooting, and also while adjusting programmable parameters.
MONITOR MENU
DISPLAY
VARIABLE RANGE DESCRIPTION
Temp -55–+127°C Controller’sinternaltemperature.
Battery Voltage model specic Battery voltage.
1212S-2xxx: 0.0 – 38.2 V
1212S-3xxx: 0.0 – 55.0 V
Motor Voltage model specic Voltage drop between the motor terminals.
1212S-2xxx: -27.4 – +27.4 V
1212S-3xxx: -41.1 – +41.1 V
Motor Thermal Cutback 0–100 % Current cutback during motor overtemperature,
as a percentage of max current.
100% = no cutback.
Armature Current -100 – +100 A Measured motor armature current.
Current Limit 0–100 A Ultimate current limit of the controller, taking
into account boost mode, thermal protection,
etc.
Resistance 0–854 m
Ω Measured system resistance, when the
motor is stalled.
Throttle 0–100 % Available throttle input.
Mode Input On , Off Status of the mode switch (at J1-4).
Forward Input On , Off Status of the forward switch (at J1-10).
Reverse Input On , Off Status of the reverse switch (at J1-12).
Interlock Input On , Off Status of the interlock input switch (at J1-6).
EMR Input On , Off Status of the emergency reverse switch
(belly button switch, at J1-14).
Lift Lockout Input On , Off Status of the lift lockout input signal from
Curtis 906 (at J1-9).