Curtis 1232E/34E/36E/38E & 1232SE/34SE/36SE Manual, os 30
129
24 NOVEMBER 2015
8 — VCL
ENABLE_EMER_REV()
This function is used to engage emergency reverse using VCL. The EMR Type
parameter must be set to = 1 in order for the Enable_Emer_Rev() function to op-
erate. If the system emergency reverse state is enabled (EMR_State bit variable
= On), the emergency reverse function will operate according to the Emergency
Reverse parameter settings; see page 68. To view the current emergency reverse
state, see Monitor » Inputs: Emer Rev on the 1313/1314 programmer.
When the EMR_Type is set to = 1 and neither the Enable_Emer_Rev() nor the
Disable_Emer_Rev() function has been called, the state for emergency reverse is
Off (EMR_State bit variable = Off).
Syntax Enable_Emer_Rev()
Parameters None.
Returns
0 – Emergency reverse not enabled.
1 – Emergency reverse successfully enabled.
Error Codes None.
Example Enable_Emer_Rev()
This will enable the emergency reverse function.
DISABLE_EMER_REV()
This function is used to disengage emergency reverse using VCL. The EMR
Type parameter must be set to = 1 in order for the Disable_Emer_Rev() function
to operate. If the system emergency reverse state is disabled (EMR_State bit
variable = Off), the emergency reverse function will stop operating and normal
motor control function will resume (including an HPD/SRO check if the HPD/SRO
Enable parameter is set to On). To view the current emergency reverse state, see
Monitor » Inputs: Emer Rev on the 1313/1314 programmer.
When the EMR_Type is set to = 1 and neither the Enable_Emer_Rev() nor the
Disable_Emer_Rev() function has been called, the state for emergency reverse is
Off (EMR_State bit variable = Off).
Syntax Disable_Emer_Rev()
Parameters None.
Returns
0 – Emergency reverse not disabled.
1 – Emergency reverse successfully disabled.
Error Codes None.
Example Disable_Emer_Rev()
This will disable the emergency reverse function.