Table 6 TROUBLESHOOTING CHART, cont’d
PROGRAMMER LCD DISPLAY
CODE
EFFECT OF FAULT
POSSIBLE CAUSE
SET/CLEAR CONDITIONS
9 — DIAGNOSTICS & TROUBLESHOOTING
49 Parameter Change Fault 1. is is a safety fault caused by a Set: Adjustment of a parameter setting
ShutdownMotor;
change in certain parameter that requires cycling of KSI.
ShutdownMainContactor; settings so that the vehicle will not Clear: Cycle KSI.
ShutdownEMBrake;
operate until KSI is cycled.
Shutdownrottle;
For example, if a user changes the
FullBrake.
rottle Type this fault will appear
and require cycling KSI before the
vehicle can operate.
51–67 OEM Faults 1. ese faults can be defined by the Set: See OEM documentation.
(See OEM documentation.)
OEM and are implemented in the Clear: See OEM documentation.
application-specific VCL code. See
OEM documentation.
68 VCL Run Time Error 1. VCL code encountered a runtime Set: Runtime VCL code error condition.
VCL error. Clear: Edit VCL application software to
2. See Monitor menu » Controller: fix this error condition; ash the new
VCL Error Module and VCL Error. compiled software and matching
is error can then be compared to parameter defaults; cycle KSI.
the runtime VCL module ID and
error code definitions found in the
specific OS system information file.
69 External Supply Out of Range 1. External load on the 5V and 12V Set: e external supply current (combined
None, unless a fault action
supplies draws either too much or current used by the 5V supply [pin 26]
is programmed in VCL. too little current. and 12V supply [pin 25]) is either greater
2. Fault Checking Menu parameters than the upper current threshold or lower
Ext Supply Max and Ext Supply Min than the lower current threshold. e two
are mis-tuned. thresholds are defined by the External
3. See Monitor menu » Outputs: Supply Max and External Supply Min
Ext Supply Current. parameter settings (page 54).
Clear: Bring the external supply current
within range.
71 OS General 1. Internal controller fault. Set: Internal controller fault detected.
Clear: Cycle KSI.
72 PDO Timeout 1. Time between CAN PDO messages Set: Time between CAN PDO messages
Shutdownrottle;
received exceeded the PDO received exceeded the PDO Timeout
CAN NMT State set Timeout Period. Period.
to Pre-operational.
Clear: Cycle KSI or receive CAN NMT
message.
ShutdownMotor;
ShutdownMainContactor;
ShutdownEMBrake;
Shutdownrottle;
ShutdownInterlock;
ShutdownDriver1;
ShutdownDriver2;
ShutdownDriver3;
ShutdownDriver4;
ShutdownPD;
FullBrake.
ShutdownMotor;
ShutdownMainContactor;
ShutdownEMBrake;
Shutdownrottle;
ShutdownInterlock;
ShutdownDriver1;
ShutdownDriver2;
ShutdownDriver3;
ShutdownDriver4;
ShutdownPD;
FullBrake.