EasyManua.ls Logo

Curtis 1268 - Page 65

Curtis 1268
66 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Curtis 1268 Manual, Rev. D A-9
APPENDIX A: EMC & ESD DESIGN CONSIDERATIONSAPPENDIX D: SPECIFICATIONS
D-1
APPENDIX D
SPECIFICATIONS
NOMINAL ARMATURE FIELD
BATTERY 2 MIN 2 MIN
MODEL VOLTAGE RATING RATING
NUMBER (volts) (amps) (amps)
1268-54XX 36–48 400 50
1268-55XX 36–48 500 50
SPECIFICATIONS: 1268 CONTROLLER
Nominal input voltage 36 V or 48V
PWM operating frequency 16 kHz
Electrical isolation to heatsink 500 V ac (minimum)
Logic enable and logic power input
voltage (minimum) 16.8 V
Logic enable and logic power input
current (no contactors engaged) 160 mA without programmer; 200 mA with programmer
Logic input voltage >20.0 V High; <7.5 V Low
Logic input current 10 mA
Operating ambient temperature range -40°C to 50°C (-40°F to 122°F)
Heatsink overtemperature cutback starts at 85°C (185°F); cutoff at 95°C (203°F)
Heatsink undertemperature cutback 50% armature current at -25°C (-13°F)
Package environmental rating IP64, IP67
Weight 3.9 kg (8.5 lb)
Dimensions (L×W×H) 229 × 178 × 81 mm (9.0" × 7.0" × 3.2")