Error 5: Drive Communication Issue
Cause:
Loss of communication with the drive, the drive has not given a valid response in 350- 400ms.
Service:
Power outages are most suspect.
Check the power cord, the power source (plug, outlet, cleanliness of power, brown-outs, etc.) and
internal communication cabling.
If the drive controller shuts down communication while the display is powered up, it can store this
error.
Check the communications cabling from the console to the motor controller.
Check the motor connector at the motor controller. If the cable tie holding the cable is too tight it may
cause a loose connection. If so, snip the cable tie and secure the motor connection.
If the data cable is routed alongside the cube or line filter it may flag unnecessary errors. Try to route
the cable closer to the frame away from the line filter.
Can also occur if a 230V motor controller is accidentally installed in a 115V unit