Error 8: Approaching Over-Temperature
Cause:
Drive is reporting a temperature of 100+°C
Service:
Open controller and vacuum or blow out accumulated debris.
Verify the drive’s fan is functional, unclogged, and the heat sink vanes are clear of debris.
Verify controller is secured to the mounting plate tightly.
Inquire on conditions in which the unit generated the error condition (user weight, speed, incline,
etc.).