Error 9: MCC Watchdog triggered
Cause:
A software task has failed, causing a delay in the routine running of the code. If the delay is long enough,
a hardware timer in the processor will re-boot the processor. When the processor comes up, it will
communicate what caused the reset (watchdog vs. normal power reset.) Watchdog resets are logged
as Error 9. Power resets are not logged.
Service:
Possible causes of this watchdog error include ESD (Static Electricity) or hardware failures in the display
and/or handset board.
Check the CHR grips for conductivity and ensure they aren’t shorted to the frame or pinched.
Verify the membranes and decals are not fatigued, cracked or show signs of moisture intrusion.
Ensure the GFX ground lead is secured correctly, and all screws holding the MCC are tight.
Check the rear MCC grounding tab for a tight fit.
If the error occurs often, replace the MCC. If associated with membrane faults 6 or 16, a good assumption
is ESD affected the membrane or thumb controls and they need replacing.
Page 72 of 209
Cybex 625T Treadmill Part Number

Other manuals for CYBEX 625T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CYBEX 625T and is the answer not in the manual?

CYBEX 625T Specifications

General IconGeneral
User Weight Capacity400 lbs
Speed Range0.5 - 12.4 mph
Incline Range0% to 15%
DisplayLED
Heart Rate MonitoringContact and wireless
Running Area60" x 20" (152 x 51 cm)

Related product manuals