MC‐BUSOPERATION
©CyrusAudioLtdJun2014 19 Cyrus6DAC,Cyrus8DACservicemanualIssue1
MC‐BUS
MC‐BUSisasystemwhichprovidescommunicationbetweenthecontrolsystemsofanumber
of Cyrus products. The communication takes the form of a serial data stream which is sent
froma'master'productandreceivedandrepeatedby'slave'products.Thedataisthuspassed
from one product to another around a loop. The master product should then receive the
message back which confirms that loop connections have been correctly made. Cyrus
amplifiers are 'master' products and send commands following certain key sequences.
Products such as CDplayersand tuners are'slaves'and onlylisten to MC‐BUSforcommands
whichmaybeappropriate.
MC‐BUSsystemtest
The MC‐BUS system can be tested by substituting the amplifier into a known working Cyrus
systemwithaCDplayerortuner.NotethatMC‐BUSmustbeconnectedasaclosedloop.Itis
also important to connect the audio signal cables between components to provide an
adequate
groundreturnpath fortheMC‐BUSsignals.Switchon thepowertothesystemand
setall components to Standby.Selectinganinputonthe amplifier will now activateboththe
amplifier and the selected device (tuner or CD as connected). When the amplifier is set to
Standby,allother
componentsconnectedtotheMC‐BUSloopwillalsosettoStandby.
MC‐BUSout
MC‐BUSout
MC‐BUSin
MC‐BUSin
Amplif ier
Tuner,CDpla yeretc .