UniFlux
30 and UniFlux 120
Operating Instructions
Original instructions
30
120
cytiva.com

Table of Contents

Questions and Answers

  • W
    wallryanSep 23, 2025
    Why is there a slow response to pH changes in cytiva UniFlux 30 Laboratory Equipment?
    • P
      Philip FosterSep 23, 2025
      If there is a small or slow response to pH changes in Cytiva Laboratory Equipment, the electrode membrane might be contaminated. Clean the electrode.
  • D
    Daniel RobertsAug 25, 2025
    How to troubleshoot little or no flow in cytiva UniFlux 30?
    • T
      Thomas StevensAug 25, 2025
      If you experience little or no flow in Cytiva Laboratory Equipment, verify that the connected inlet is actually in use. Ensure that inlet containers are not placed too low relative to the pump. Confirm that liquid is being supplied to the pump by checking the inlet containers. Also, examine the tubing from the inlet container for issues such as excessive length, too small internal diameter, narrow sections, or blockages. Finally, check for a malfunctioning valve at the container battery limit.
  • C
    Caitlin MedinaAug 25, 2025
    What causes high flow in the air integrity test of Cytiva Laboratory Equipment?
    • K
      Kathy MarshallAug 26, 2025
      If the flow is too high during the air integrity test for Cytiva Laboratory Equipment, it may be due to a clogged filter. Try cleaning the filter to resolve this issue.
  • S
    Seth VillaAug 26, 2025
    What causes low flow in the air integrity test of cytiva UniFlux 30 Laboratory Equipment?
    • A
      Alicia OlsonAug 27, 2025
      If the flow is too low during the air integrity test for Cytiva Laboratory Equipment, it may be because the pores in the membrane or fibers have become larger than the nominal size, or because the fibers or membranes are broken. In either case, you should change the filter.
  • T
    Tiffany FletcherAug 27, 2025
    What to do if there is little or no flow in cytiva UniFlux 30?
    • R
      Randy TaylorAug 27, 2025
      If you see little or no flow in Cytiva Laboratory Equipment, check the pump hose. If it is broken or damaged, contact your local Cytiva representative.
  • M
    Marcus MendozaSep 16, 2025
    How to connect the system to UNICORN in Cytiva Laboratory Equipment?
    • E
      Eric BanksSep 16, 2025
      To establish a connection between the system and UNICORN on Cytiva Laboratory Equipment: 1. Open a System Control module. 2. Select the System ?Connect menu command or click the Connect to system toolbar icon. This will open the System Connect dialog box. 3. Select the system you want to connect to. 4. Click OK.
  • M
    michaelbauerSep 13, 2025
    Why is the pH reading incorrect on cytiva UniFlux 30 Laboratory Equipment?
    • J
      Julie MillerSep 13, 2025
      If the pH reading appears to be incorrect on Cytiva Laboratory Equipment, calibrate the pH-sensor.
  • S
    Stacy WilliamsonSep 15, 2025
    How to fix 'No system found' when starting UNICORN on cytiva UniFlux 30?
    • M
      Margaret KimSep 15, 2025
      To resolve the issue of no system being found when starting up UNICORN on Cytiva Laboratory Equipment, ensure the system is switched on, check the communication cable and connectors, and reboot the PC by shutting down Windows, switching off the system power, waiting at least 5 seconds, and then restarting the system.
  • T
    Teresa VargasSep 5, 2025
    What to do if the pump of Cytiva Laboratory Equipment does not reach desired pressure?
    • Q
      qgoodwinSep 5, 2025
      If the pump does not reach the desired pressure in Cytiva Laboratory Equipment, check if the regulator is set below the desired pressure and adjust it accordingly. Also, check the oil level in the reservoir; if it's low, add oil until it reaches approximately 60% of the reservoir's volume (3 L).
  • B
    Brittany LeeSep 3, 2025
    How to troubleshoot high outlet pressure in cytiva UniFlux 30 Laboratory Equipment?
    • P
      powellkarlSep 3, 2025
      If you observe too high outlet pressure in Cytiva Laboratory Equipment, verify that the connected outlet is actually in use and that outlet containers are not placed too high relative to the pump. Check the tubing to the outlet container for issues such as excessive length, too small internal diameter, narrow sections, or blockages. Also, check for non-functioning valves and any malfunctioning valve at the container battery limit.

cytiva UniFlux 30 Specifications

General IconGeneral
Applicationsdiafiltration
Flow RateUp to 30 L/min
Column SizeNot applicable
ConnectivityEthernet
Temperature Range4 to 40°C
pH Range2