Where the link partner is powered on with errors, this command can detect whether the
error is open, short, or crosstalk. In this case this command can also detect the distance of
the error.
Where the link partner is powered down with no errors and the link is down, this
command can detect the cable length.
When the link partner is powered down with errors, this command can detect whether
the error is open, short, or crosstalk. In this case this command can also detect the
distance of the error.
When there is no link partner with no errors, this command can detect the cable length.
When there is no link partner with errors, this command can detect whether the error is
open, short, or crosstalk. In this case this command can also detect the distance of the
error.
The Cable length range that can be detected is as follows:
Smaller than 50m (<50m)
Between 50m and 80m (50m~80m)
Between 80m and 100m (80m~100m)
Greater than 100m (>100m)
Note: This test will consume a low number of packets. Since this test is for copper cable,
the port with fiber cable will be skipped from the test.
Restrictions
Only Administrator, Operator and Power-User level users can issue this command. (EI Mode Only
Command)
Example
To test the cable on ports 1 to 4, and 8: