16
Automatic closure
In order to avoid the gate remaining open, you can choose to make it close after a preset time, which
ranges from 1 second to 9 min 59 sec. The time begins running when the gate stops moving.
If the Open or Close push-buttons are pressed, the time is reset to zero and begins running again.
Setting automatic closure (C50)
1. Step to C50 (automatic closure setting).
2. Set the desired time for automatic closure.
NB: The gate will now close without warning.
The gate must be fitted with a ‘fail safe’ safety buffer, photocell or vehicle detector if automatic closure
is to be used. Otherwise it may begin closing even if there is something in its path.
Additional warning are available by fitting a supplementary control card that can activate a warning
light or audible device.
Stop key, restart automatic closure
An adjustable stop function is provided. When stop has been pressed, it is normally desirable to block
automatic closure so that it does not start immediately. Blocking times can be selected from 20
seconds to 9 minutes and 59 seconds, this is adjusted in C52. To disable automatic closure after stop
has been actuated, 0 should be set in C53.
NB. If the gate should always close after a stop instruction 1 should be set in C53 to avoid the gate
remaining open.
Setting automatic closure after stop has been actuated (C52,C53)
1. Step to C53 (setting automatic closure after stop has been actuated).
2. Set the desired function. 0=no automatic closure after stop,
1=automatic closure blocked for time set.
3. Step to C52 and set time for blockage of automatic closure.
Photocell/loop closure
With this function, automatic closure time begins to be counted from when a vehicle passes the loop.
In order to activate the function, a time must be set in C51. The time set should be the time after which
the gate will close if no vehicle passes. If the loop is successively actuated and then not actuated (i.e.
a vehicle has passed) the gate closes after automatic closure time.
Set photocell/loop closure (C51,C54)
1. Step to C51 (setting of "max. open time in loop closure").
2. Enter the desired time after which the gate should close if no vehicle passes.
Closure may take place immediately if the loop is not activated, or after the gate has fully opened.
1. Step to C54, (”type of loop closure”).
2. Set the desired type of closure.
1=vehicle passes, gate opens to fully open and closes after automatic closure time.
0=vehicle passes, gate stops immediately and closes after automatic closure time.