Inter lock function
Two or more EP102 panels can communicate with each other and send interlocks and start signals
between the gates.
Attention
Commissioning and function tests for each gate shall be carried out according to section
“Commissioning”, before the parameters are set between the gates.
Program version 1.03 or later is required for inter lock functions.
The program has a memory for opening but not for closing.
Heat Lock.
You can have a heat lock by letting only one door open at a time. A signal opens the first door, which
closes automatically. When the first door is closed it opens the second door.
Draught exclusion in a building with two doors.
Doors can be interlocked so that only one door can be opened at a time.
Entrance with barrier and gate operating together.
Barriers open and close rapidly but have a low level of security. A gate has higher security but takes
longer to open and close. By combining both these elements you can achieve high security along with