54
Email setting interface is shown as in Figure 3- 46.
Figure 3- 46
SMTP server: Please input your email SMTP server IP here.
Port: Please input corresponding port value here.
User name: Please input the user name to login the sender email box.
Password: Please input the corresponding password here.
Sender: Please input sender email address here.
Title: Please input email subject here. System support English character and Arabic number.
Max 32-digit.
Interval: The send interval ranges from 0 to 3600 seconds. 0 means there is no interval.
Please note system will not send out the email immediately when the alarm occurs. When the
alarm, motion detect or the Abnormality event activates the email, system sends out the email
according to the interval you specified here. This function is very useful when there are too many
emails activated by the Abnormality events, which may result in heavy load for the email server.
Health email enable: Please check the box here to enable this function. This function allows
the system to send out the test email to check whether the connection is OK or not. Select
this function and then set interval for those test email. The send interval ranges from 30 to
1440 minutes.
Note: Click test button to test whether current EMAIL config is OK.
3.2.4.5.7 Alarm Center
This interface is reserved for you to develop. If alarm occurs locally, its alarm signal will be
uploaded to alarm center. For you to use alarm center, please set server IP and port first. When