Thermistors Si121295
14 Removal Procedure
6. Thermistors
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure Points
1. Remove the assembly of
thermistors.
Be careful not to lose the
fixture for the thermistor.
1
Release the discharge
pipe thermistor.
2
Cut the clamp and pull
out the outdoor heat
exchanger thermistor.
3
The thermistors are
united as an assembly.
2. Remove the liquid / gas
pipe thermistors.
1
Cut the clamp.
(R7630)
Discharge pipe thermistor
(R18790)
fixture
(R7631)
Outdoor heat
exchanger thermistor
(R7632)
Outdoor
temperature
thermistor
(R7634)