6 | Application guidelines
Installer reference guide
55
EPRA08~12EAV3+W1 + ETBH/X12EF6V+9W
Daikin Altherma 3 H MT W
4P634885-1 – 2021.03
6.4.6 DHW pump for tank preheating
Setup
a DHW tank
b Cold water IN
c Hot water OUT (shower (field supply))
d Motorised 3‑way valve (field supply)
e DHW pump (field supply)
f Non‑return valve (field supply)
The DHW pump is field-supplied and its installation is the responsibility of the
installer. For the electrical wiring, see "9.3.5To connect the domestic hot water
pump"[4118].
For the standalone DHW tank: If there is no electrical backup heater in the space
heating circuit, you must install a DHW pump for tank preheating.
Configuration
The indoor unit can control DHW pump operation. For more information, see
"10Configuration"[4130].
6.5 Setting up the energy metering
Via the user interface, you can read out the following energy data:
- Produced heat
- Consumed energy
You can read out the energy data:
- For space heating
- For space cooling
- For domestic hot water production
You can read out the energy data:
- Per month
- Per year