Daikin Altherma 3 H MT W - Setting up the Power Consumption Control

Daikin Altherma 3 H MT W
296 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 | Application guidelines
Installer reference guide
59
EPRA08~12EAV3+W1 + ETBH/X12EF6V+9W
Daikin Altherma 3 H MT W
4P634885-1 – 2021.03
Setup
Connect power meter1 to X5M/5 and X5M/6.
Connect power meter2 to X5M/3 and X5M/4.
See "9.3.4To connect the electricity meters"[4117].
Power meter types
Power meter 1: Single- or three-phase power meter according to the power
supply of the outdoor unit.
Power meter2:
- In case of a single-phase backup heater configuration, use a single-phase
power meter.
- In other cases, use a three-phase power meter.
Example
Single-phase outdoor unit with a three-phase backup heater:
e efe
ihg
j
A B C
b
a
d

c
5
8
0
1
5
0
0
0
5
8
0
1
5
0
0
0
A Outdoor unit
B Indoor unit
C DHW tank
a Electrical cabinet (L
1
/N): Preferential kWh rate power supply
b Electrical cabinet (L
1
/L
2
/L
3
/N): Normal kWh rate power supply
c Power meter (L
1
/N)
d Power meter (L
1
/L
2
/L
3
/N)
e Fuse (L
1
/N)
f Fuse (L
1
/L
2
/L
3
/N)
g Outdoor unit (L
1
/N)
h Indoor unit (L
1
/N)
i Backup heater (L
1
/L
2
/L
3
/N)
j Booster heater (L
1
/N)
6.6 Setting up the power consumption control
You can use the following power consumption controls. For more information
about the corresponding settings, see "Power consumption control"[4208].
# Power consumption control
1 "6.6.1Permanent power limitation"[460]
Allows you to limit the power consumption of the entire heat pump
system (sum of indoor unit and backup heater) with one permanent
setting.
Limitation of power in kW or current in A.