10 | Configuration
Installer reference guide
139
EVLQ05+08CA + EHYHBH05A + EHYHBH/X08A + EHYKOMB33AA
Daikin Altherma hybrid heat pump
4P355634-1G – 2022.09
Quick wizard: Options
Domestic hot water settings
Following settings must be made accordingly.
# Code Description
[A.2.2.1] [E‑05] Domestic hot water preparation:
0 (No): NOT possible
1 (Yes)(default): Possible
[A.2.2.2] [E‑06] Domestic hot water tank installed in the system?
0 (No)(default): the domestic hot water will be
produced by the boiler when there is a
demand.
1 (Yes): the domestic hot water will be
produced by the tank.
Note: For Switzerland, setting MUST be "1".
[A.2.2.3] [E‑07] What kind of domestic hot water tank is
installed?
4 (Type 5). EKHWP.
6 (Type 7) Third-party tank.
Range: 0~6.